Özet: During the CE EMC certification process for lighting luminaires, low-frequency magnetic field radiated disturbance is an easily overlooked yet mandatory test item. The Three Loop Antenna, also known as a large loop antenna, is a dedicated receiving antenna for magnetic field radiated disturbance measurement in the frequency band of 9kHz to 30MHz. Specified explicitly by the CISPR 15 standard, this type of antenna is widely used in pre-compliance and formal certification EMI tests for LED luminaires, LED drivers, lighting control modules and other related products. Taking the LISUN VVLA-30M Three Loop Antenna as the research subject, this paper describes its working principle, structural features, interface configuration and matching test scheme, introduces the networking method between the Three Loop Antenna and EMI receiver, analyzes its application value in daily inspection, R&D pre-testing and third-party certification scenarios of lighting laboratories. It also summarizes the CISPR 15 requirements for low-frequency magnetic field radiated disturbance, helping test engineers understand the position of the Three Loop Antenna in a complete EMI test system and providing references for lighting laboratories to build a compliant low-frequency magnetic field test station.
MKS Üç Döngü Anten consists of three mutually orthogonal loop coils aligned along the X, Y and Z axes in three-dimensional space, which can simultaneously capture magnetic field signals from all directions. There is an obvious difference between the testing mechanism of magnetic field radiated disturbance and electric field radiated disturbance. In the low-frequency band from 9kHz to 30MHz, the interference energy emitted by lighting equipment is dominated by the magnetic field component. Ordinary biconical antennas and log-periodic antennas have extremely low sensitivity for magnetic field signals and cannot perform effective measurements in this frequency range. The Three Loop Antenna is specially designed to match this frequency characteristic. During testing, the Three Loop Antenna separately acquires magnetic field components on the three axes, and the receiver calculates the maximum value of spatial magnetic field disturbance to judge whether the magnetic radiation level of the sample meets standard limits.
The coils of the LISUN VVLA-30M Three Loop Antenna are wound with low-loss conductors, and the coil skeleton is made of insulating material with low dielectric constant and low loss to reduce the influence of dielectric loss on the antenna factor and ensure stable receiving performance across the full operating frequency range. The overall antenna structure is reinforced. The coil spacing and orthogonal angles are calibrated and fixed before delivery to prevent the antenna factor from shifting caused by deformation during transportation and installation. No built-in amplifier circuit is integrated inside the antenna; magnetic field signals are coupled purely by the coils. Its simple and stable structure brings small long-term drift, which is suitable for repeated long-duration testing. The Three Loop Antenna is delivered with a calibration certificate containing antenna factors for the full frequency band. The test software invokes these factors when calculating disturbance field strength and converts the voltage value read by the receiver into standard magnetic field strength.
The Three Loop Antenna is equipped with a 50Ω BNC general-purpose signal port. 50Ω is the standard characteristic impedance of EMC RF test systems, which guarantees impedance matching of the RF link between the antenna and receiver and minimizes measurement errors induced by signal reflection. This port has good universality and is compatible with standard RF coaxial cables. Laboratories can directly use existing 50Ω RF cables for signal connection without customized adapters.
In terms of compatible host instruments, this Three Loop Antenna can work directly with the LISUN EMI-9K series EMI receivers to form a complete magnetic field radiated disturbance test system. The receiver is pre-installed with CISPR 15 standard test templates, and the software supports antenna factor import for the Three Loop Antenna, automatic triaxial magnetic field scanning and maximum value recording. The whole system is easy to commission, with streamlined data reading and report generation. Meanwhile, the Three Loop Antenna is not locked to a single brand of host. Its signal output conforms to common industry specifications and is compatible with most mainstream EMI receivers of the same type available on the market. Laboratories that already own EMI receivers from other brands can connect this antenna directly, lowering the investment threshold for equipment upgrade. In the pre-test stage of lighting luminaires, many laboratories adopt this combination to identify low-frequency magnetic field non-compliance risks before sending samples to third-party laboratories, avoiding extra cost and cycle loss caused by certification failure.
CISPR 15 is the core standard for radio disturbance of electrical lighting and similar equipment. It clearly stipulates that the Three Loop Antenna shall be adopted for measuring magnetic field radiated disturbance within 9kHz~30MHz, which is one of the mandatory EMI test items for CE certification of lighting products. Many laboratories only set up electric field radiation test systems for frequencies above 30MHz. Without a Three Loop Antenna, they cannot complete all test items specified in CISPR 15 and cannot produce fully compliant test data.
For test arrangement, the Three Loop Antenna shall be placed above the ground reference plane as required by the standard, and the luminaire under test shall be mounted on a non-conductive support at the specified height with the defined separation distance from the Three Loop Antenna. Magnetic field signals of X, Y and Z directions are collected sequentially during the test, and the software automatically calculates the composite maximum value. The test site shall stay away from high-power power supplies, frequency converters and other external interference sources as far as possible, otherwise excessive background magnetic field will raise the test noise floor and interfere with result evaluation. Since the Three Loop Antenna itself cannot suppress background noise, site environmental assessment is indispensable before formal testing. Before each official test, operators need to check the version of antenna factors and confirm that receiver bandwidth, detector mode and sweep settings comply with CISPR 15 requirements, so as to guarantee reproducible test results accepted by certification bodies.

| + | Belirlenmesi VVLA-30M Üç Döngü Anten | Corresponding CISPR 15 Test Requirements |
|---|---|---|
| Frekans aralığı | 9kHz~30MHz | Covers the low-frequency magnetic disturbance test band for lighting luminaires |
| Çıkış Bağlantı Noktası | BNC, 50Ω | Matches the standard RF input impedance of EMI receivers |
| Bobin Yapısı | Triaxial orthogonal loop coils | Captures X/Y/Z three-dimensional magnetic field components and calculates maximum value |
| Compatible Hosts | LISUN EMI-9K series EMI receivers, compatible with mainstream EMI receivers | Supports multiple existing EMI test platforms with good expandability |
| Sağlanan Belgeler | Factory antenna factors, calibration certificate | Enables field strength conversion and meets traceability requirements for certification audit |
| Applicable DUTs | LED luminaires, LED drivers, smart lighting controllers | Designed for CISPR 15 magnetic radiation testing of lighting products |
With the rapid growth of smart lighting, dimmable drivers and luminaires with wireless control functions, low-frequency magnetic disturbance generated by internal switching power supplies and PWM dimming circuits has become more prominent. Many products pass high-frequency electric field tests smoothly but fail the 9kHz~30MHz magnetic field test. As the only compliant receiving antenna for this frequency band, the Three Loop Antenna has become standard equipment for professional lighting EMI laboratories.
For in-house laboratories of luminaire manufacturers, deploying a Three Loop Antenna paired with an EMI receiver helps locate magnetic disturbance sources quickly in the R&D phase. Engineers can carry out rectification by adjusting PCB layout, adding magnetic shielding and optimizing filter circuits to resolve non-compliance issues in advance. For third-party testing laboratories, a Three Loop Antenna test station is required to undertake complete CISPR 15 certification services and enrich the EMI testing capability for lighting products. The LISUN VVLA-30M Üç Döngü Anten balances stability and compatibility. It can work seamlessly with the matching EMI-9K receiver and also connect to users’ existing test hosts, flexibly fitting lab construction plans of different scales. Under increasingly strict CE certification regulations, a low-frequency magnetic field test system equipped with a Three Loop Antenna is an essential foundation for lighting manufacturers to control certification risks and improve product compliance performance.
Etiketler:VVLA-30ME-posta hesabınız yayımlanmayacak. Gerekli alanlar işaretlendi *